Replaced filter opened all vents returns not blocked checked combustion air intake and exhaust and they are not blocked. In this video i explain what the flame roll out is why it trips and what you would need to do next.
Crown Boiler Flame Rollout Switch G4am0600240c Part 960122
Flame rollout switch keeps tripping. Just resetting the switch and going on is like turning off a fire alarm and leaving the fire burning. He found no real problems but did say some of the intake and exit pvc piping wasnt properly glued so he fixed them. If flames roll out the front of the burner its a strong sign. Roll out switch keeps tripping. The flame roll out switch is a safety switch that shuts the furnace off if flames come out the front of the furnace. This rollout switch that keeps tripping sits right on the metal above the burners.
Published on oct 10 2018 one common symptom of a failing or blocked heat exchanger is the roll out switch tripping. So this other company closed some holes of the topmost burner so that the flame doesnt fan out as it does for the burners below. I noticed that there was some rust hanging down from the top of the intake where the flame shoots into and so i cleaned this off and i watched it and there was no flame roll out. The flame roll out switch. Flame roll out switch keeps tripping on my rheem. Flame rollout on side keeps tripping.
I can reset it. This happens because the flames are not being drawn into and through. The furnace runs fine for a day or so. Ever since he left no heat. Inspected burner nozzles and they look good they are only 3 yrs old from when furnace was converted to propane only thing i can see is that there is a bit of residual flame around the ends of the tubes that feed the heat exchanger. That has created another problem now.
I reset it and it tripped again. Tripped rollout switch anytime you have to reset a rollout switch on a furnace warning alarms should go off in your head. The switch is not the problem it is a symptom of a very serious problem. The jet of flame does not completely shoot into the heat exchanger the box containing the propane. The flame roll out switch tripped. If the furnace limit or rollout switch senses that over heating occurs then it trips the rollout switch to prevent an unsafe over heating condition.
I had a service technician out for yearly maintenance on my gibson kg7sc earlier this week. I have not seen any flames coming out of the exchanger intake it just appears to be 3 nice blue jets of flame blowing into the intake on the exchanger. My furnace flame roll switch keeps tripping. Now if it does it. Unfortunately in most cases a tripped. I can reset it and the furnace will function fine for about 30 to 36 hours my furnace flame roll switch keeps tripping.
Is the flame roll out switch tripped in your furnace.