I had to go back to the breaker box to find the breaker for the second circuit and shut that one off as well. This can cause fire shock and.
Dedicated Electrical Circuits For Appliances
Can two separate circuits be in the same junction box. Can you have two separate circuits in one box junction box. I will have a four gang box near door room light light outside door and two separate covered porch circuits. Both circuits are properly grounded at the sub panel. Sparkyinak 178075 052208 0806 pm. When neutral wires of two or more separate circuits are connected at other than the main panel the electicity has multiple return paths resulting in net currents. Jdevlin 178061 052208 0151 pm.
That is two cables enter from different breakers and they tie to cables exiting but the two circuits arent connected except for the grounds if that is required. Ground wires from different circuits in same box re. He could not give me the code. Ground wires from different circuits in same box re. I know nec puts significant restrictions on having different circuits suppling outlets in same box but i havent found any mention of doing this with switch boxes. The only concern would be the total box fill.
2 electrician told me i can run 123 for dishwasher and food disposer and have one receptacle under the sink with upper and bottom connected on different dedicated circuits but from one 123 cable. I usually tie them together but this time i thought it was cleaner to separate them. Just seems strange to have two separate breakered circuits in the same wall junction box. Can more than one circuit be run through a single junction box. As the title states. Based on the nec the wire fill would be calculated at 20 for each conductor for 14 gauge wire and 225 for 12 gauge wire.
The device or switch counts as 2x for the largest wire connected to it or each in the box. Can two different circuits go through the same junction box. If 2 of the circuits are on a mwbc 143 cable then you would just need to keep the 2 neutrals separate. He is saying the associated with those circuit conductors only refers to each individual circuit not all the separate circuits in the same box. Assuming the junction box has the proper capacity i want to run a separate circuit through that box so as to split off a circuit which will then go two different ways to power up an outlet on one wall and two other outlets on a different wall. The inspector said that for the past 30 years the code has required that all equipment grounds be tied together regardless of what circuit they originate from.
If the box has clamps they are counted as. Junction box wiring electrical question. Only exception is isolated grounds live awesome kevin carosa re. Well lets put it this way how would you extend the circuits to a distribution board if it needed to be moved 2 ft away from its current position and none of the existing cabling would reach. In this instance i kept the equipment grounds from the 2 circuits separate. All the ground wires count as 1x of the largest ground in the box.
Not the breaker box but rather the junction box seems dangerous. They have two separate breakers and use 14 2 wire to the current double gang box. I have a ceiling fan all wired correctly. The box is plastic and contains a lighting circuit and a small appliance branch circuit. The porch circuits are already present but i dont think these would pass current code. I think there is just 14 3 leaving the box to.
The answer is yes you can have 2 separate circuits in the same box they can have a splice also but not needed in your case.